Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Circulation ; 144(19): 1543-1552, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34459659

RESUMO

BACKGROUND: Percutaneous closure of the left atrial appendage (LAA) is an alternative to chronic oral anticoagulation to reduce stroke risk in patients with nonvalvular atrial fibrillation. The Amulet IDE trial (Amplatzer Amulet Left Atrial Appendage Occluder IDE Trial) was designed to evaluate the safety and effectiveness of the dual-seal mechanism of the Amulet LAA occluder compared with the Watchman device. METHODS: Patients with nonvalvular atrial fibrillation at increased risk of stroke were randomly assigned (1:1) to undergo percutaneous implantation of a LAA occluder with the Amulet occluder or Watchman device. The primary end points included safety (composite of procedure-related complications, all-cause death, or major bleeding at 12 months), effectiveness (composite of ischemic stroke or systemic embolism at 18 months), and the rate of LAA occlusion at 45 days. Prespecified secondary end points included a composite of all stroke, systemic embolism, or cardiovascular/unexplained death at 18 months, major bleeding at 18 months, and superiority test of the 3 primary end points. RESULTS: A total of 1878 patients were enrolled. The Amulet occluder was noninferior to the Watchman device for the primary safety end point (14.5% versus 14.7%; difference=-0.14 [95% CI, -3.42 to 3.13]; P<0.001 for noninferiority). Major bleeding and all-cause death were similar between groups (10.6% versus 10.0% and 3.9% versus 5.1%, respectively). Procedure-related complications were higher for the Amulet occluder (4.5% versus 2.5%), largely related to more frequent pericardial effusion and device embolization. The Amulet occluder was noninferior to the Watchman device for the primary effectiveness end point (2.8% versus 2.8%; difference=0.00 [95% CI, -1.55 to 1.55]; P<0.001 for noninferiority), and the composite of stroke, systemic embolism, or cardiovascular/unexplained death (5.6% versus 7.7%, difference=-2.12 [95% CI, -4.45 to 0.21]; P<0.001 for noninferiority). The rate of major bleeding was similar between groups (11.6% versus 12.3%; difference=-0.71 [95% CI, -3.72 to 2.31]; P=0.32 for superiority). LAA occlusion was higher for the Amulet occluder than for the Watchman device (98.9% versus 96.8%; difference=2.03 [95% CI, 0.41-3.66]; P<0.001 for noninferiority; P=0.003 for superiority). CONCLUSIONS: The Amulet occluder was noninferior for safety and effectiveness of stroke prevention for nonvalvular atrial fibrillation compared with the Watchman device and superior for LAA occlusion. Procedure-related complications were higher with the Amulet occluder and decreased with operator experience. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02879448.


Assuntos
Dispositivo para Oclusão Septal/normas , Acidente Vascular Cerebral/terapia , Idoso , Feminino , Humanos , Masculino
2.
Int Heart J ; 61(4): 848-850, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32728003

RESUMO

Right ventricular (RV) dysfunction may occur after cardiac surgery and it is not rare after corrective repair of tetralogy of Fallot (TOF). If traditional treatments with volume management, infusion of inotropic agents, and use of pulmonary vasodilators cannot stabilize the patient, extracorporeal membrane oxygenation (ECMO) or a ventricular assist device (VAD) will be considered as the last resort. Here, we report a young infant patient with RV failure after corrective repair of TOF and without closure of an atrial septal defect (ASD), who was rescued by veno-venous (VV) -ECMO.


Assuntos
Septo Interatrial/cirurgia , Oxigenação por Membrana Extracorpórea/métodos , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/terapia , Assistência ao Convalescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia/métodos , Insuficiência Cardíaca/fisiopatologia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Comunicação Interatrial/cirurgia , Coração Auxiliar , Humanos , Lactente , Masculino , Dispositivo para Oclusão Septal/normas , Tetralogia de Fallot/diagnóstico por imagem , Resultado do Tratamento
3.
Rev. cuba. pediatr ; 92(1): e783, ene.-mar. 2020. tab
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1093746

RESUMO

Introducción: El cateterismo intervencionista corrige las cardiopatías complejas, donde el dispositivo Amplatzer es el más usado y está disponible en Cuba. Objetivo: Evaluar el cateterismo intervencionista con Amplatzer, en el cierre de la comunicación interauricular ostium secundum. Métodos: Estudio de evaluación, longitudinal y prospectivo en 92 pacientes. El cierre de la comunicación por cateterismo con Amplatzer, se realizó en el Cardiocentro Pediátrico William Soler (2010-2016). Se utilizaron variables demográficas, ecocardiográficas (transtorácicas y transesofágicas) antes, durante y al año del cateterismo. Se observaron las complicaciones. La evaluación clínica y ecocardiográfica se realizó al año poscateterismo. Los pacientes a quienes se les realizó el proceder en el 2016, se evaluaron a los 6 meses. Resultados: Se encontraron diferencias significativas en el sexo (p<0,05): femenino 64,1 por ciento con homogeneidad para la edad (p= 0,244): media 9,8 años ( 5 desviaciones estándar. Precateterismo: 28,3 por ciento eran desnutridos y 17,4 por ciento delgados; poscateterismo la desnutrición mejoró significativamente (p= 0,000): desnutridos 9,8 por ciento y delgados 8,7 por ciento. El diámetro medio del defecto por ecocardiografía transcateterismo fue significativo (p= 0,000). Transcateterismo: 98,9 por ciento con cierre de defecto, 16,3 por ciento con insuficiencia tricúspidea y 4,3 por ciento con insuficiencia mitral. Poscateterismo: 98,9 por ciento con Amplatzer bien colocado. Hubo complicaciones inmediatas en 8,7 por ciento (arritmias, derrame pericárdico y embolización). Al año se detectó cortocircuito residual pequeño (n= 1) e insuficiencias valvulares auriculoventriculares (n= 3). La evolución fue satisfactoria (n= 91). Conclusiones: La evolución del cierre de la comunicación interauricular ostium secundum con dispositivo Amplatzer es satisfactoria, con mejoras de la desnutrición(AU)


Introduction: The interventional catheterization corrects complex heart diseases, and the Amplatzer device is the most widely used and is available in Cuba. Objective: To assess the interventional catheterization with Amplatzer device in the ostium secundum atrial septal closure. Methods: Longitudinal and prospective evaluation study in 92 patients. The closure of the communication by Amplatzer catheterization was performed in the William Soler Pediatric Cardiocenter of (2010-2016). Demographic and echocardiographic (transthoracic and transesophageal) variables were used before, during, and at the year of the catheterization. Complications were observed. Clinical and echocardiographic assessment was made a year after catheterism. The patients who underwent the procedure in 2016 were evaluated at 6 months. Results: Significant differences were found in the sex (p< 0.05): Female 64.1 t percent with homogeneity of the age (p= 0.244): average 9.8 years ( 5 standard deviations. Pre-catheterism: 28.3 percent were malnourished and 17.4 percent thin; post-catheterism: malnutrition improved significantly (p= 0.000): 9.8 percent malnourished and 8.7 percent thin. The average diameter of the defect by transcatheter echocardiography was significant (p= 0.000). Transcatheter: 98.9 percent : with default closure, 16.3 percent with tricuspid insufficiency and 4.3 percent with mitral regurgitation. Post-catheterism: 98.9 percent with Amplatzer device correctly positioned. There were immediate complications in 8.7 percent (arrhythmia, pericardial effusion, and embolization). A year after, small residual short circuit was detected (n= 1), and atrioventricular valve regurgitation (n= 3). The evolution was satisfactory (n= 91). Conclusions: The evolution of ostium secundum atrial septal defect´s closure with Amplatzer device is satisfactory and improves malnutrition(AU)


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Cateterismo Cardíaco/métodos , Septo Interatrial/fisiopatologia , Dispositivo para Oclusão Septal/normas , Estudos Prospectivos , Estudos Longitudinais
4.
Pediatr Cardiol ; 41(3): 591-598, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32055941

RESUMO

To identify suitable cases and reduce failure/complication rates for percutaneous ventricular septal defect (VSD) closure, we aimed to (1) study causes of device failure and (2) compare outcomes with different VSD types and devices in a high-volume single center with limited resources. Retrospective data of 412 elective percutaneous VSD closure of isolated congenital VSDs between 2003 and 2017 were analyzed. Out of 412, 363 were successfully implanted, in 30 device implantation failed, and in 19 the procedure was abandoned. Outcome was assessed using echocardiography, electrocardiography, and catheterization data (before procedure, immediately after and during follow-up). Logistic regression analyses were performed to assess effects of age, VSD type, and device type and size on procedural outcome. Median [interquartile range] age and body surface area were 6.6 [4.1-10.9] years and 0.7 [0.5-1.0] m2, respectively. Device failure was not associated with age (p = 0.08), type of VSD (p = 0.5), device type (p = 0.2), or device size (p = 0.1). Device failure occurred in 7.6% of patients. As device type is not related to failure rate and device failure and complication risk was not associated with age, it is justifiable to use financially beneficial ductal devices in VSD position and to consider closure of VSD with device in clinically indicated children.


Assuntos
Comunicação Interventricular/terapia , Dispositivo para Oclusão Septal/normas , Cateterismo Cardíaco , Criança , Pré-Escolar , Bases de Dados Factuais , Ecocardiografia , Eletrocardiografia , Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Dispositivo para Oclusão Septal/economia , Resultado do Tratamento
6.
Arch Cardiovasc Dis ; 112(8-9): 532-542, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31378692

RESUMO

BACKGROUND: Unlike previous randomized clinical trials (RCTs), recent trials and meta-analyses have shown that transcatheter closure of patent foramen ovale (PFO) reduces stroke recurrence risk in young and middle-aged adults with an otherwise unexplained PFO-associated ischaemic stroke. AIM: To produce an expert consensus on the role of transcatheter PFO closure and antithrombotic drugs for secondary stroke prevention in patients with PFO-associated ischaemic stroke. METHODS: Five neurologists and five cardiologists with extensive experience in the relevant field were nominated by the French Neurovascular Society and the French Society of Cardiology to make recommendations based on evidence from RCTs and meta-analyses. RESULTS: The experts recommend that any decision concerning treatment of patients with PFO-associated ischaemic stroke should be taken after neurological and cardiological evaluation, bringing together the necessary neurovascular, echocardiography and interventional cardiology expertise. Transcatheter PFO closure is recommended in patients fulfilling all the following criteria: age 16-60 years; recent (≤6 months) ischaemic stroke; PFO associated with atrial septal aneurysm (>10mm) or with a right-to-left shunt>20 microbubbles or with a diameter≥2mm; PFO felt to be the most likely cause of stroke after thorough aetiological evaluation by a stroke specialist. Long-term oral anticoagulation may be considered in the event of contraindication to or patient refusal of PFO closure, in the absence of a high bleeding risk. After PFO closure, dual anti-platelet therapy with aspirin (75mg/day) and clopidogrel (75mg/day) is recommended for 3 months, followed by monotherapy with aspirin or clopidogrel for≥5 years. CONCLUSIONS: Although a big step forward that will benefit many patients has been taken with recent trials, many questions remain unanswered. Pending results from further studies, decision-making regarding management of patients with PFO-associated ischaemic stroke should be based on a close coordination between neurologists/stroke specialists and cardiologists.


Assuntos
Isquemia Encefálica/prevenção & controle , Cateterismo Cardíaco/normas , Cardiologia/normas , Forame Oval Patente/terapia , Prevenção Secundária/normas , Acidente Vascular Cerebral/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/epidemiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Consenso , Feminino , Forame Oval Patente/diagnóstico , Forame Oval Patente/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Medição de Risco , Fatores de Risco , Dispositivo para Oclusão Septal/normas , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento , Adulto Jovem
7.
Braz J Cardiovasc Surg ; 34(3): 344-351, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31310474

RESUMO

OBJECTIVES: To compare the advantages and disadvantages of perventricular and percutaneous procedures for treating isolated ventricular septal defect (VSD). METHODS: A total of 572 patients with isolated VSD were selected in our hospital between January 2015 and December 2016. The patients' median age and weight were five years (1-26 years) and 29 kg (9-55 kg), respectively. The median diameter of VSD was 6.0 mm (5-10 mm). Patients were divided into two groups. In group A, perventricular device closure was performed in 427 patients; in group B, 145 patients underwent percutaneous device closure. RESULTS: Four hundred twelve patients in group A and 135 patients in group B underwent successful closure. The total occlusion rate was 98.5% (immediately) and 99.5% (3-month follow-up) in group A, which were not significantly different from those in group B (97.7% and 100%, respectively). Patients in group A had longer intensive care unit (ICU) stay than those in group B, but patients in group B experienced significantly longer operative times than those in group A. The follow-up period ranged from 8 months to 1.5 year (median, 1 year). During the follow-up period, late-onset complete atrioventricular block occurred in two patients. No other serious complications were noted in the remaining patients. CONCLUSION: Both procedures are safe and effective treatments for isolated VSD. The percutaneous procedure has obvious advantages of shorter ICU stay and less trauma than the perventricular procedure. However, the perventricular procedure is simpler to execute, results in a shorter operative time, and avoids X-ray exposure.


Assuntos
Comunicação Interventricular/cirurgia , Dispositivo para Oclusão Septal/normas , Adolescente , Adulto , Angiografia/métodos , Insuficiência da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/cirurgia , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Pré-Escolar , Ecocardiografia/métodos , Desenho de Equipamento , Feminino , Comunicação Interventricular/diagnóstico por imagem , Humanos , Lactente , Tempo de Internação , Masculino , Duração da Cirurgia , Estudos Retrospectivos , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
8.
Rev. bras. cir. cardiovasc ; 34(3): 344-351, Jun. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1013473

RESUMO

Abstract Objectives: To compare the advantages and disadvantages of perventricular and percutaneous procedures for treating isolated ventricular septal defect (VSD). Methods: A total of 572 patients with isolated VSD were selected in our hospital between January 2015 and December 2016. The patients' median age and weight were five years (1-26 years) and 29 kg (9-55 kg), respectively. The median diameter of VSD was 6.0 mm (5-10 mm). Patients were divided into two groups. In group A, perventricular device closure was performed in 427 patients; in group B, 145 patients underwent percutaneous device closure. Results: Four hundred twelve patients in group A and 135 patients in group B underwent successful closure. The total occlusion rate was 98.5% (immediately) and 99.5% (3-month follow-up) in group A, which were not significantly different from those in group B (97.7% and 100%, respectively). Patients in group A had longer intensive care unit (ICU) stay than those in group B, but patients in group B experienced significantly longer operative times than those in group A. The follow-up period ranged from 8 months to 1.5 year (median, 1 year). During the follow-up period, late-onset complete atrioventricular block occurred in two patients. No other serious complications were noted in the remaining patients. Conclusion: Both procedures are safe and effective treatments for isolated VSD. The percutaneous procedure has obvious advantages of shorter ICU stay and less trauma than the perventricular procedure. However, the perventricular procedure is simpler to execute, results in a shorter operative time, and avoids X-ray exposure.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Adulto Jovem , Dispositivo para Oclusão Septal/normas , Comunicação Interventricular/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Fatores de Tempo , Angiografia/métodos , Ecocardiografia/métodos , Estudos Retrospectivos , Resultado do Tratamento , Estatísticas não Paramétricas , Desenho de Equipamento , Bloqueio Atrioventricular/cirurgia , Duração da Cirurgia , Comunicação Interventricular/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Tempo de Internação
12.
Int J Cardiol ; 279: 47-50, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30344060

RESUMO

BACKGROUND: Patent foramen ovale (PFO) closure after a cryptogenic cerebral ischemic event is a routinely procedure. The most used device is Amplatzer™ PFO Occluder 25 mm, but PFOs with complex anatomy require larger device for closure. We compared Amplatzer™ Septal Occluder (ASO) device versus Amplatzer™ PFO Occluder 30 or 35 mm (A-PFO 30/35) about the safety of procedure and the presence of residual shunt during the follow-up. METHODS: From June 2002 to July 2016, 355 patients (pts) with PFO undergone closure at our institution. Among these ones, 70 pts (19.7%) had a PFO with complex anatomy and a single device with greater diameter was implanted. In these cases, the following devices were used: Gore® Septal Occluder (GSO) in 4 pts; ASO device in 33 pts (group I) and A-PFO 30/35 in 33 pts (group II). Patients treated with GSO device were excluded by our analysis. RESULTS: Comparing group I and group II, there weren't complications during the procedures. Two patients of group II were lost at follow-up. At last follow-up, 1 pt of group I (3%) and 10 pts of group II (32.3%) had a residual shunt (p < 0.01). 7 of 10 pts of group II and the only 1 of group I with residual shunt underwent a complete closure by Amplatzer™ Vascular Plug (AVP) devices. CONCLUSIONS: ASO devices and A-PFO 30/35 devices are both safe to close complex PFO; but A-PFO 30/35 is associated with a more incidence of residual shunt.


Assuntos
Cateterismo Cardíaco/normas , Desenho de Equipamento/normas , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Dispositivo para Oclusão Septal/normas , Adulto , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/normas , Desenho de Equipamento/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal/tendências , Resultado do Tratamento
13.
Medicine (Baltimore) ; 97(50): e13747, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30558097

RESUMO

RATIONALE: Coronary artery fistulae (CAF) are uncommon heart lesions, but they are the most frequent significant hemodynamic congenital coronary anomaly. Transcatheter closure is an alternative treatment and a variety of techniques and devices were reported to use for the closure of congenital coronary fistulae. PATIENT CONCERNS: We reported a 5-year-10-month-old boy who was diagnosed as CAF at birth. Follow-up transthoracic echocardiography showed persistent CAF and progressed dilatation of the left coronary artery. DIAGNOSES: Coronary angiography showed torturous coronary vessel and CAF at the distal segment of the left circumflex artery (LCX). INTERVENTION: Antegrade approach with Amplatzer Vascular Plug was used due to the retrograde approach failed and showed a good result. OUTCOMES: During a 3-year follow-up period, the patient showed no symptoms and demonstrated good exercise ability. Follow-up coronary angiography showed the Amplatzer vascular plug was located at an adequate position without a residual shunt from the CAF, and the diameter of the left coronary artery regressed when compared to previous angiography results. LESSONS: The antegrade approach is a feasible method for closing CAF if torturous vessels are noted and fistulae occur at the distal portion of the coronary artery. A large randomized study or case series are needed to investigate the comparison of antegrade and retrograde method for the closure of CAF.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Fístula Vascular/diagnóstico por imagem , Assistência ao Convalescente , Cateterismo Cardíaco/métodos , Pré-Escolar , Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/patologia , Vasos Coronários/patologia , Ecocardiografia/métodos , Humanos , Masculino , Dispositivo para Oclusão Septal/normas , Resultado do Tratamento , Fístula Vascular/patologia , Fístula Vascular/cirurgia
14.
Int Heart J ; 59(5): 1161-1165, 2018 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-30012923

RESUMO

Hemodynamically significant patent ductus arteriosus (PDA) in preterm infants increases morbidity and mortality. Here we describe a 12-day-old neonate with a huge PDA who developed pulmonary hemorrhage following disseminated intravascular clotting and multiple organ failure. Medical treatment or surgical ligation could not be performed because of the patient's poor condition. Transcatheter closure using a commercially available device (Amplatzer Vascular Plug II) successfully treated the huge PDA without major complications. The Amplatzer Vascular Plug II approach might become a new option for PDA closure in small infants, including those who are critically ill.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/cirurgia , Dispositivo para Oclusão Septal/normas , Estado Terminal/mortalidade , Estado Terminal/terapia , Coagulação Intravascular Disseminada/complicações , Permeabilidade do Canal Arterial/diagnóstico , Hemorragia/complicações , Humanos , Recém-Nascido , Pneumopatias/patologia , Masculino , Insuficiência de Múltiplos Órgãos/complicações , Dispositivo para Oclusão Septal/estatística & dados numéricos , Índice de Gravidade de Doença , Resultado do Tratamento
15.
BMJ Case Rep ; 20182018 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-29735491

RESUMO

Platypnoea Orthodeoxia syndrome is defined by dyspnoea and hypoxaemia exacerbated by orthostatic positioning and alleviated in recumbency. This condition has been reported in association with pulmonary, hepatic and cardiac disease. We describe a case herein of a 79 year old female who developed severe hypoxaemia and dyspnoea post laparoscopic cholecystectomy. A difference in arterial blood gas oxygen tension was demonstrated in the supine and erect positions on arterial blood gas analysis. A Patent Foramen Ovale (PFO) with a right to left shunt was evident on echocardiogram employing colour doppler and agitated normal saline studies. Definitive management, with closure of the patent foramen ovale lead to a complete resolution of symptoms and normalisation of arterial blood gas parameters in both the supine and erect positions.


Assuntos
Cateterismo Cardíaco/instrumentação , Colecistectomia Laparoscópica/efeitos adversos , Dispneia/diagnóstico , Forame Oval Patente/diagnóstico por imagem , Hipóxia/diagnóstico , Idoso , Gasometria/métodos , Dispneia/sangue , Dispneia/etiologia , Ecocardiografia Doppler em Cores/métodos , Feminino , Humanos , Hipóxia/sangue , Hipóxia/etiologia , Complicações Pós-Operatórias/epidemiologia , Doenças Raras , Dispositivo para Oclusão Septal/normas , Síndrome , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 29(8): 1089-1095, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29727507

RESUMO

BACKGROUND: The efficacy and safety of combining left atrial appendage closure (LAAC) plus atrial fibrillation (AF) catheter ablation (CA) in a single procedure has been established, but the optimal combination strategy has not been thoroughly elucidated to date. OBJECTIVE: We aimed to investigate the impact of different combination strategies on clinical outcomes. METHODS: Eighty-two consecutive patients with symptomatic AF (mean CHA2 DS2 -VASc score 4.4 ± 1.4, mean HAS-BLED score 3.5 ± 1.0) were enrolled. LAAC with the Watchman device was performed either before (occlusion-first group, N  =  52) or after (ablation-first group, N  =  30) CA. Procedural and clinical data were retrospectively analyzed to evaluate the advantages of each strategy. RESULTS: Complete device occlusions were achieved in 92.3% and 90.0% of patients, respectively (P  =  0.719). Neither acute nor chronic peridevice leak greater than 5 mm was detected. Oral anticoagulants were held in all patients, except two (one in each group) with asymptomatic device-related thrombi. AF-free success rates were comparable between groups with a mean follow-up of 11.2 ± 7.3 months (75.0% vs. 70.0%, log-rank P  =  0.311). The new peridevice leak rate was significantly lower in the occlusion-first group (7.7% vs. 26.7%, P  =  0.019). Multivariate logistic regression demonstrated that the combination strategy was independently associated with the new peridevice leak (P  =  0.025, OR 13.3). CONCLUSIONS: Both occlusion-first and ablation-first strategies were efficacious and safe as combined procedures in patients with nonvalvular AF; however, the occlusion-first strategy was associated with lower new peridevice leak rates at follow-up.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter/normas , Dispositivo para Oclusão Septal/normas , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Ablação por Cateter/métodos , Terapia Combinada/métodos , Terapia Combinada/normas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
17.
Respir Med ; 137: 213-218, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29605207

RESUMO

A persistent air leak (PAL) can be caused by either an alveolar-pleural fistula (APF) or bronchopleural fistula (BPF). Complications from PAL lead to an increase in morbidity and mortality, prolonged hospital stay, and higher resource utilization. Pulmonary physicians and thoracic surgeons are often tasked with the difficult and often times frustrating diagnosis and management of PALs. While most patients will improve with chest tube thoracostomy, many will fail requiring alternative bronchoscopic or surgical strategies. Herein, we review the bronchoscopic and surgical diagnostic and treatment options for PAL as it pertains to the field of interventional pulmonology and thoracic surgery.


Assuntos
Fístula Brônquica/diagnóstico por imagem , Broncoscopia/instrumentação , Fístula/diagnóstico por imagem , Doenças Pleurais/diagnóstico por imagem , Fístula Brônquica/complicações , Fístula Brônquica/patologia , Fístula Brônquica/cirurgia , Broncoscopia/métodos , Tubos Torácicos/normas , Fístula/complicações , Fístula/cirurgia , Humanos , Tempo de Internação/estatística & dados numéricos , Doenças Pleurais/etiologia , Doenças Pleurais/patologia , Pleurodese/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Dispositivo para Oclusão Septal/normas , Toracostomia/normas
18.
Int J Cardiol ; 261: 54-57, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29551254

RESUMO

AIM: To describe our initial experience with the Occlutech Duct Occluder (ODO) for percutaneous closure of patent ductus arteriosus (PDA). METHODS: Retrospective review of patients undergoing transcatheter PDA closure with the ODO in 2 academic centers. RESULTS: From April 2013 to September 2017, 42 patients underwent PDA closure. Median age at implantation was 34 months (range 4 months-68 years) and median weight was 12 kg (range 4.1-57 kg). Ducts were Krichenko type A duct (n = 34), type E (n = 6), and type C (n = 2). The mean duct diameter was 3.76 mm (range 1.69 to 9.95 mm, median 3.1 mm). Implantation succeeded in all. There was neither device embolization nor hemolysis. At device release, immediate angiogram showed a small residual shunt in 54.7%. During follow-up, Doppler echocardiography demonstrated 71% of full occlusion at day one, rising to 95% at one month and 100% at one year and half after implantation. The mean maximal systolic pressure gradient in left pulmonary artery was 4.2 ±â€¯4.3 mm and across the distal aortic arch 5.4 ±â€¯4.7 mm Hg. No patient had any significant stenosis with clinical relevance. CONCLUSIONS: ODO is safe and effective in transcatheter closure of PDA including relatively large sized ducts. The results are satisfactory with a high level of full occlusion and a low rate of complications. Further evaluation with larger studies and longer follow-up will be required to confirm these preliminary good results.


Assuntos
Cateterismo Cardíaco/tendências , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/cirurgia , Desenho de Prótese/tendências , Dispositivo para Oclusão Septal/tendências , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/normas , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/normas , Estudos Retrospectivos , Dispositivo para Oclusão Septal/normas , Resultado do Tratamento , Adulto Jovem
19.
Interv Cardiol Clin ; 7(2): 151-158, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29526284

RESUMO

AMPLATZER devices preceded WATCHMAN occluder in 2002 for catheter-based left atrial appendage occlusion. The AMPLATZER technique facilitates simultaneous closure of atrial shunts using two devices through one gear. Randomized WATCHMAN follow-up data showed a mortality benefit over warfarin. AMPLATZER data make this likely valid for the strategy. Particularly young people with atrial fibrillation should be offered left atrial appendage occlusion because the risk is confined to the intervention and early postintervention period. Guidelines should be adapted to make this progress in prevention of stroke and bleeding in patients with atrial fibrillation accessible for all, in the sense of a mechanical vaccination.


Assuntos
Apêndice Atrial/cirurgia , Dispositivo para Oclusão Septal/normas , Oclusão Terapêutica/instrumentação , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fluoroscopia/métodos , Humanos , Desenho de Prótese/tendências , Implantação de Prótese/instrumentação , Acidente Vascular Cerebral/prevenção & controle , Varfarina/uso terapêutico
20.
Interv Cardiol Clin ; 7(2): 229-242, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29526291

RESUMO

Transcatheter left atrial appendage occlusion is increasingly used for stroke prevention in atrial fibrillation. The technique has proven effective and safe in randomized trials and multiple observational studies. The procedure is challenging due to the complex anatomy of the left atrial appendage; accurate cardiac imaging is essential for procedural guidance. Transesophageal echocardiography is the gold standard, but cardiac computed tomography (CT) has gained increasing interest within recent years. Cardiac CT offers high-resolution imaging allowing for preprocedural anatomic evaluation and device sizing, but may also be useful for exclusion of left atrial appendage thrombus, and follow-up assessment of residual peri-device leaks.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Dispositivo para Oclusão Septal/normas , Tomografia Computadorizada por Raios X/métodos , Assistência ao Convalescente , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana , Humanos , Acidente Vascular Cerebral/prevenção & controle , Trombose/diagnóstico por imagem , Trombose/prevenção & controle , Trombose/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...